Technical
Data for EKO-Line Boilers |
| Parameters |
Unit |
EKO-Line
25 |
EKO-Line
40 |
EKO-Line
60 |
EKO-Line
80 |
| Power range |
KW |
5 ÷ 31 |
8 ÷ 40 |
15-60 |
25-80 |
| Efficiency |
% |
85 |
85 |
85 |
85 |
| Weight |
Lb |
1080 |
1212 |
1808 |
2315 |
| Height |
A inch |
51.5 |
59 |
60.5 |
60.5 |
| Height of heating water exit |
B inch |
48.5 |
56 |
56.5 |
56.5 |
| Height of heating water entry |
C inch |
8.3 |
6.0 |
7.9 |
7.9 |
| Height of outlet valve |
D inch |
5.1 |
2.7 |
5.1 |
5.1 |
| Height of chimney flue |
E inch |
37.4 |
50.0 |
45.7 |
45.7 |
| Width including handle |
F inch |
24.8 |
24.8 |
30.3 |
30.3 |
| Width including casing |
G inch |
23.6 |
23.6 |
29.1 |
29.1 |
| Depth |
H inch |
41.1 |
41.1 |
53.5 |
52.7 |
| Hot water exit |
I inch |
12.6 |
12.6 |
24.0 |
24.0 |
| Diameter of chimney flue |
J inch |
6 |
6 |
8 |
8 |
| Diameter of hot water exit |
inch |
2.0 |
2.0 |
2.5 |
2.5 |
| Diameter of hot water entry |
inch |
2.0 |
2.0 |
2.5 |
2.5 |
| Kind of connection |
- |
thread |
thread |
thread |
thread |
| Diameter of drain valve |
inch |
0.5 |
0.5 |
0.5 |
0.5 |
| Water capacity |
Gal |
20 |
25 |
47 |
54 |
| Volume of loading chamber (gasification) |
Gal |
31 |
49 |
82 |
123 |
| Power consumption |
W |
35 |
35 |
55 |
55 |
| Moisture of wood: |
|
|
|
|
|
| - recommended |
% |
|
15 - 25 |
|
|
| - acceptable |
% |
|
10 - 35 |
|
|
| Maximum log diameter |
inch |
7 |
7 |
7 |
7 |
| Maximum length of logs |
inch |
20 |
20 |
25 |
39 |
| Average temperature of flue gas |
F |
|
460 |
|
|
| Max. working pressure |
PSI |
|
25 |
|
|
| Required chimney draught |
Pa |
|
15 - 20 |
|
|
| Voltage / frequency |
V/Hz |
|
120V/60Hz |
|
|